Rheem® Endeavor® RA14AY60AJ1NA Air Conditioner, 5 ton Tonnage, R-454B Refrigerant, 1 Stages, 208-230 V, 15.2 SEER2
Rheem® Endeavor® RA14AY60AJ1NA Air Conditioner, 5 ton Tonnage, R-454B Refrigerant, 1 Stages, 208-230 V, 15.2 SEER2
Manufacturer: Rheem Manufacturing
Brand: Rheem®
Part #: 309500
MPN: RA14AY60AJ1NA
CPN:
| BTU Cooling Rating | : | 56,000 Btu/hr |
| Compressor Type | : | Scroll |
| Depth | : | 35.75 in |
| EER2 | : | 12.0 |
| Energy Star Certified | : | Yes |
| Height | : | 45.00 in |
| Liquid Line Size | : | 3/8 in |
| Max Breaker Size | : | 50 A |
| Minimum Circuit Ampacity (MCA) | : | 31 A |
| Model Number | : | RA14AY |
| Number of Rows | : | 2 |
| Number of Stages | : | Single |
| Packaged Depth | : | 38.38 in |
| Packaged Height | : | 46.50 in |
| Packaged Width | : | 38.38 in |
| Phase | : | 1 ph |
| Product Family | : | Endeavor Line Classic Series |
| Product Weight | : | 266 lb |
| Refrigerant Type | : | R-454B |
| SEER2 | : | 15.2 |
| Shipping Weight | : | 273 lb |
| Sound Level | : | 76 dBA |
| Suction Line Size | : | 7/8 in |
| Tonnage | : | 5.0 Ton |
| Voltage Rating | : | 208/230 V |
| Width | : | 35.75 in |
Rheem® Air Conditioner, Tonnage: 5 ton, R-454B Refrigerant, 1 Stages, BTU Cooling Rating: 56000 Btu/hr, 208-230 V, SEER2: 15.2, EER2: 12, 1 ph Phase, Yes, 76 dB Sound Level, Endeavor® Line Classic® Series, Scroll Compressor, 3/8 in Liquid Line, 7/8 in Suction Line, 45 in Height, 35-3/4 in Width, 35-3/4 in Depth, Minimum Circuit Ampacity (MCA): 31 A, 2 Rows
- 7mm Condenser Copper Coil Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
- Swept Wing Fan Technology Features quieter operation and improved unit acoustics
- PlusOne® Triple Service Access 15 in. wide, industry leading corner service access, two fastener, removable corner and individual louver panels - makes repairs easier and faster
- Designing for Sustainability with Low GWP For 2025, the Environmental Protection Agency (EPA) has set a global warming potential (GWP) limit of 700 for refrigerant used in heating and cooling systems
- This new requirement will result in a 78% lower GWP than previous-generation refrigerants with only minimal changes to system installation
- For us, this is another step toward our continued sustainability goal of reducing greenhouse gas emissions, while still delivering an exceptional level of energy efficient, dependable comfort
- An integrated one-box, patented design featuring the A2L sensor and mitigation board, offering easier commissioning with a single component and simplified wiring configuration, compatibility with any 24V thermostat application and system protection by automatically pausing outdoor unit operation - if excess refrigerant is detected